The Teltonika TRB140 is a compact 4G LTE router. This guide covers hardware setup, the manual APN configuration, an equivalent configuration script you can paste in directly, and a few optional features worth turning on: remote access, PING reboot, and SMS reboot.
Before you start, make sure your SIM is activated in the Simbase dashboard. If it isn't, see Enable or disable a SIM card first.
For a visual walkthrough alongside this guide, see Teltonika's TRB140 setup video.
Unscrew the panel to access the SIM slot.
Insert your Simbase SIM into the router's SIM holder and close the panel.
Screw the antenna onto its connection point.
Connect the power cable to the router and plug it into an outlet.
The router takes a few minutes to start up. Connect your computer to it via the Ethernet port.
Open a browser and go to 192.168.2.1.
Log in with username admin and password admin01.
If this is your first login, you'll be prompted to change the default password, follow the prompts.
Click MODE in the top right corner and switch to advanced mode. The remaining steps assume advanced mode is on.
Go to Network → Interfaces.
Click the pencil icon on the MOB1S1A1 entry.
Turn off Auto APN.
Leave everything else at its default, except:
APN: --custom--
Custom APN: simbase
Scroll down and click Save & Apply.
Your SIM should now connect to the internet.
For background on what an APN does and how Simbase's APN profiles work, see Set up the APN.
If you'd rather paste a script than click through the UI, this does the same APN setup plus a set of recommended and optional extras.
Log in to the router and go to System → Custom Script.
Clear the input field.
Paste the script below and click Save & Apply.
# Set APN to Simbase (required)uci set network.mob1s1a1.disabled='0'uci set network.mob1s1a1.force_link='0'uci set network.mob1s1a1.stp='0'uci set network.mob1s1a1.igmp_snooping='0'uci set network.mob1s1a1.method='nat'uci set network.mob1s1a1.pdptype='ip'uci set network.mob1s1a1.force_apn='-1'uci set network.mob1s1a1.apn='simbase'uci set network.mob1s1a1.auth='none'uci set simcard.@sim[0].auto_apn='0'uci commit && reload_config# Set router config to Advanced mode (highly recommended)uci set vuci.main.advanced='1'# Set MTU to 1200 (highly recommended)uci set network.mob1s1a1.mtu='1200'# Enable remote HTTP (optional)uci set firewall.@rule[11].enabled='1'uci commit && reload_config# Enable remote SSH (optional)uci set firewall.@rule[10].enabled='1'uci commit && reload_config# Enable SMS reboot (optional)uci set sms_utils.@rule[0].status_sms='0'uci set sms_utils.@rule[0].authorization='no'uci commit && reload_config# Change LAN IP and subnet (optional)uci set network.lan.ipaddr='192.168.2.1'uci set network.lan.netmask='255.255.255.0'uci set network.lan.proto='static'uci commit && reload_config# Enable PING reboot (highly recommended)uci set ping_reboot.@ping_reboot[0].enable='1'uci commit && reload_configexit 0
The # (required), # (highly recommended), and # (optional) comments mark which blocks you can safely remove if you don't want that behaviour. The required block is the first one, it's what sets the APN to simbase.
For a guided version of this step, see below:
Teltonika routers support remote configuration, useful if you need to reach the device's admin panel without being on its local network. See below Teltonika's remote access walkthrough :
We strongly recommend enabling PING reboot. Once enabled, the router pings Google's DNS (8.8.8.8) every 5 minutes. If a ping fails, the router assumes there's a mobile connection problem and reboots itself, recovering from silent drops without anyone needing to notice or intervene.
Check out Teltonika's PING reboot walkthrough below:
If the router ever loses its data connection entirely (so it can't be reached over the internet), SMS reboot gives you a way to force a hardware reboot remotely. See Teltonika's SMS reboot walkthrough to enable it.
Once enabled, send an SMS containing the text reboot to the device's number to trigger a reboot. For how to send SMS from Simbase, see SMS.
Processor: ARM Cortex-A7, 1.2 GHz
Memory: 256 MB DDR3 RAM, 256 MB NAND flash
Networking: 4G LTE (FDD/TDD), 3G (WCDMA/CDMA), 2G
Power: 12V DC adapter or USB
Operating temperature: -40°C to 75°C
Dimensions: 74.5 x 25 x 64.4 mm
Weight: 134 g
Certifications: CE/RED, EAC, RoHS, WEEE
These specs apply to the TRB140 specifically, other Teltonika models will differ. For full details, see Teltonika's official TRB140 documentation.
onfirm your SIM shows as active in the Simbase dashboard first. If it does, double-check the APN value is exactly simbase under Network → Interfaces → MOB1S1A1.
Yes, the script sets the same APN values as the manual configuration. Running both isn't harmful, but there's no need, pick one.
PING reboot only triggers after a failed ping to 8.8.8.8, not on slow responses. If you're seeing frequent reboots, that usually points to a genuine connectivity issue worth investigating.


© 2026 Simbase Connect. All rights reserved.